Triplex Service Drop Cable 6AWG Minex #6
Code Word: Minex
Size AWG (Phase Conductors): 6
Voltage: 600V
Number of cores: Triplex
Package : Export wooden drum & iron wooden drum or as customer require
Email:uvlead@aliyun.com
Email:tlfast@aliyun.com
6-6-6 Minex Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
ASTM B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
ASTM B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
Phase Conductor | Strand or Compressed 1350-H19 Series Aluminum Conductor. |
Neutral(Messenger )Conductor | Bare AAAC messenger. Optional constructions include a messenger of AAC or ACSR |
Insulation | Black Cross Linked Polyethylene (XLP) Insulation. |

Rated voltage | V | 600 |
Test voltage | Veff kV/Hz | 4/50 |
Laying temperature | °C | min. -5 |
Operating temperature | °C | -30 ~ +90 |
Conductor temperature | °C | max. +90 |
Short-circuit temperature | °C/s | max. +250 /5 |
Bending radius (min.) | mm | 20 × Ø of cable |
| Code Name | Minex |
| Phase Conductor Material | AAC |
| Phase Conductor Size (awg) | 6 |
| Phase Conductor Stranding | 7 |
| Phase Conductor insulation Material | XLPE |
| Phase Conductor Insulation Thickness (mils) | 45 |
| Bare Neutral Messenger Material | AAAC |
| Bare Neutral Messenger Size(awg) | 6 |
| Bare Neutral Messenger Stranding | 7 |
| Bare Neutral Messenger Breaking Strength (Lbs) | 1110 |
| Weight Per (Lbs/1000 ft) | 102 |
| Ampacity (Amps) | 85 |
| PHASE CONDUCTORS | ACSR COMPACT BARE NEUTRAL | OVERALL | |||||||||
| SIZE (AWG OR kcmil) | NO. OF WIRES | COND. O.D. (mm) | MIN. INS. THKN. (mm) | NOM. INS. O.D. (mm) | SIZE (AWG OR kcmil) | NO. OF WIRES (A1/S1A) | RATED STRENGTH | COND. O.D. (mm) | EFFECTIVE O.D. (mm) | APPROX. | AMPACITY |
| kN | WEIGHT | ||||||||||
| (kg/km) | |||||||||||
| 4 | 7 | 5.41 | 1.04 | 7.75 | 6 | 6/1 | 5.18 | 5.03 | 15 | 220 | 125 |
| 2 | 7 | 6.88 | 1.04 | 9.14 | 4 | 6/1 | 8.14 | 6.35 | 18 | 333 | 165 |
| 1/0 | 7 | 8.53 | 1.37 | 11.6 | 2 | 6/1 | 12.4 | 8.11 | 23 | 527 | 220 |
| 2/0 | 7 | 9.65 | 1.37 | 12.6 | 1 | 6/1 | 15.5 | 8.99 | 25 | 650 | 255 |
| 3/0 | 7 | 10.7 | 1.37 | 13.8 | 1/0 | 6/1 | 18.9 | 10.1 | 28 | 803 | 290 |
| 4/0 | 7 | 12.1 | 1.37 | 15.2 | 2/0 | 6/1 | 23.5 | 11.5 | 30 | 996 | 335 |
| 266.8 | 19 | 13.6 | 1.83 | 17.7 | 3/0 | 6/1 | 29.6 | 12.8 | 35 | 1282 | 390 |
| 336.4 | 19 | 15.3 | 1.83 | 19.4 | 4/0 | 6/1 | 37.3 | 14.3 | 39 | 1588 | 450 |
| 397.5 | 19 | 16.7 | 1.83 | 20.8 | 266.8 | 26/7 | 50.1 | 16.3 | 42 | 1890 | 500 |
| 477 | 19 | 18.3 | 1.83 | 22.4 | 336.4 | 26/7 | 62.3 | 18.3 | 46 | 2277 | 560 |